The increasing integration of photovoltaic (PV) systems into low-voltage distribution networks introduces power quality concerns, particularly due to current and voltage harmonics. These harmonics can lead to increased thermal stress in distribution transformers, potentially reducing their operational lifespan. This study presents an electro-thermal modeling approach to evaluate the impact of PV-induced harmonics on the hotspot temperature of oil-immersed distribution transformers. A detailed harmonic load profile was developed based on real PV generation data and inverter characteristics. The model couples electrical harmonic analysis with thermal simulation using IEEE and IEC transformer thermal models. Results indicate that the presence of high-order harmonics, especially during peak PV output hours, can cause a hotspot temperature rise of up to 8β12β―Β°C compared to harmonic-free operation. This elevated temperature can accelerate insulation aging and compromise transformer reliability. The study highlights the need for harmonic mitigation strategies in PV-rich grids and supports transformer design optimization for harmonic resilience.
Keywords
Photovoltaic systems, harmonics, distribution transformer
References
Abdali, A., Mazlumi, K., & Rabiee, A. (2024). Harmonics impact on hotspot temperature increment of distribution transformers: Nonuniform magnetic-thermal approach. International Journal of Electrical Power and Energy Systems, 157. https://doi.org/10.1016/j.ijepes.2024.109826
Ackermann, T., Ran Andersson, G., & SΓΆ Der A, L. (2001). Distributed generation: a definition. Electric Power Systems Research, 57. www.elsevier.com/locate/epsr
AJ, C., Salam, M. A., Rahman, Q. M., Wen, F., Ang, S. P., & Voon, W. (2018). Causes of transformer failures and diagnostic methods β A review. In Renewable and Sustainable Energy Reviews, 82, 1442β1456. https://doi.org/10.1016/j.rser.2017.05.165
Awadallah, M. A., Venkatesh, B., & Singh, B. N. (2015). Impact of solar panels on power quality of distribution networks and transformers. Canadian Journal of Electrical and Computer Engineering, 38(1), 45β51. https://doi.org/10.1109/CJECE.2014.2359111
Awadallah, M. A., Xu, T., Venkatesh, B., & Singh, B. N. (2016). On the Effects of Solar Panels on Distribution Transformers. IEEE Transactions on Power Delivery, 31(3), 1176β1185. https://doi.org/10.1109/TPWRD.2015.2443715
Cazacu, E., Ionita, V., & Petrescu, L. (2018). Thermal Aging of Power Distribution Transformers Operating under Nonlinear and Balanced Load Conditions. https://doi.org/10.15598/aeee.v16i1.2701
Chen, T., Liu, Z., Wang, P., Jiang, J., & Yang, F. (2023). Temperature Simulation of 800 kVA Converter Transformer Windings Considering the Effects of High-Order Harmonics. 2023 26th International Conference on Electrical Machines and Systems, ICEMS 2023, 2589β2593. https://doi.org/10.1109/ICEMS59686.2023.10344825
Dao, T., & Phung, B. T. (2018). Effects of voltage harmonic on losses and temperature rise in distribution transformers. IET Generation, Transmission and Distribution, 12(2), 347β354. https://doi.org/10.1049/iet-gtd.2017.0498
Das, A. K., & Chatterjee, S. (2017). Finite element method-based modelling of flow rate and temperature distribution in an oil-filled disc-type winding transformer using COMSOL multiphysics. IET Electric Power Applications, 11(4), 664β673. https://doi.org/10.1049/iet-epa.2016.0446
El Batawy, S. A., & Morsi, W. G. (2017). On the impact of high penetration of rooftop solar photovoltaics on the aging of distribution transformers. Canadian Journal of Electrical and Computer Engineering, 40(2), 93β100. https://doi.org/10.1109/CJECE.2017.2694698
Fortes, R. R. A., Buzo, R. F., & de Oliveira, L. C. O. (2020). Harmonic distortion assessment in power distribution networks considering DC component injection from PV inverters. Electric Power Systems Research, 188. https://doi.org/10.1016/j.epsr.2020.106521
Gorginpour, H., Ghimatgar, H., & Toulabi, M. S. (2022). Lifetime Estimation and Optimal Maintenance Scheduling of Urban Oil-Immersed Distribution-Transformers Considering Weather-Dependent Intelligent Load Model and Unbalanced Loading. IEEE Transactions on Power Delivery, 37(5), 4154β4165. https://doi.org/10.1109/TPWRD.2022.3146154
Hajipour, E., Mohiti, M., Farzin, N., & Vakilian, M. (2017). Optimal distribution transformer sizing in a harmonic involved load environment via dynamic programming technique. Energy, 120, 92β105. https://doi.org/10.1016/j.energy.2016.12.113
Hamza, E. A., Sedhom, B. E., & Badran, E. A. (2021). Impact and assessment of the overvoltage mitigation methods in low-voltage distribution networks with excessive penetration of PV systems: A review. International Transactions on Electrical Energy Systems 31(2). https://doi.org/10.1002/2050-7038.13161
Hossain, M. S., Abboodi Madlool, N., Al-Fatlawi, A. W., & El Haj Assad, M. (2023). High Penetration of Solar Photovoltaic Structure on the Grid System Disruption: An Overview of Technology Advancement. Sustainability (Switzerland) 15(2). https://doi.org/10.3390/su15021174
IEEE Std C57.91-2011(Revision of IEEE Std C57.91-1995) : IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators Sponsored by the Transformers Committee. (2011). IEEE
IEEE Std C57.110-2018 (Revision of IEEE Std C57.110-2008) : IEEE Recommended Practice for Establishing Liquid-Immersed and Dry-Type Power and Distribution Transformer Capability When Supplying Nonsinusoidal Load Currents. (2018). IEEE